Title and Link to Calc:

Incompressible Fluid Flow : Flow in Y-Pattern Globe Valves : IFF-CRFOF-0015

Description:

Calculates flow parameters in a Y-Pattern Globe valve similar to Examples 4-1, 4-2 and 4-3 in Flow of Fluids Through Valves, Fittings, and Pipe, 1988 (reprinted 12/01), Crane Co. , K Values are calculated at complete turbulence per page page A-26 through A-29 of the reference. The flowrate of a specified liquid and 60 F water is calculated at the input pressure conditions. The flow coefficent and equivalent lengths are also calculated.

Alternative Descriptors:

Water Flow in Y-Pattern Globe Valves, K of Y-Pattern Globe Valves, Cv of Y-Pattern Globe Valves, Pressure drop in Y-Pattern Globe valves, Flow coefficient of Y-Pattern Globe valves, Head Loss in Y-Pattern Globe valves, Resistance coefficient of Y-Pattern Globe valves, Flow of Incompressible Fluids through Y-Pattern Globe Valves, Equivalent Length of Y-Pattern Globe valves.

Calc Number:

IFF-CRFOF-0015

Calc Status:

Beta

Reference:

(1) Flow of Fluids Through Valves, Fittings, and Pipe, 1988 (reprinted 12/01), Crane Co.

Reference Example(s) Modeled/Generalized:

Examples 4-1, 4-2, and 4-3 of the above reference

Calc Origination Date:

03/01/2006

Calc Originator:

RBC

Calc Revision History:

Calc Guidelines:

See the above reference

Access:

Activating this calc requires entry of the correct access code. Contact eng-calc@eng-calcs.com

Variables:

Variable Description - Description of the variable
Variable Label Description - The description of the variable as it appears in the calc.
Variable Calc Name - The calc internal variable name
Variable Units - The units for the variable
Variable Calc Upper Limit - The highest allowed value in the calc.
Variable Calc Lower Limit - The lowest allowed value in the calc.
Variable Type - Either "Output" or "Input"
Variable Format - Real Number, Text, or Integer
Variable Notes - Other comments about the variable

Variable Description: Resistance Coefficient, K, based on the upstream pipe inside (large) diameter
Variable Label Description: Resistance Coefficient [K]
Variable Calc Name: KEQ
Variable Units:
Variable Calc Upper Limit: 100000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Equivalent Length of Y-Pattern Globe Valve based on the upstream pipe inside (large) diameter
Variable Label Description: Equivalent Length
Variable Calc Name: EQL
Variable Units: FT
Variable Calc Upper Limit: 100000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Darcy Friction Factor based on the upstream pipe inside (large) diameter
Variable Label Description: Darcy Pipe Friction Factor
Variable Calc Name: FF
Variable Units:
Variable Calc Upper Limit: 100000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Flow Coefficient , Cv
Variable Label Description: Flow Coefficient [Cv]
Variable Calc Name: CV
Variable Units:
Variable Calc Upper Limit: 100000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Volumetric Flow Rate of Specified Liquid in gallons per minute
Variable Label Description: Specified Liquid Volumetric Flow Rate
Variable Calc Name: VFR
Variable Units: GPM
Variable Calc Upper Limit: 100000000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Mass Flow Rate of Specified Liquid
Variable Label Description: Specified Liquid Mass Flow Rate
Variable Calc Name: MFRS
Variable Units: LBM/SEC
Variable Calc Upper Limit: 100000000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Flow Rate of 60 F Water through Valve
Variable Label Description: Water Mass Flow Rate [60 F]
Variable Calc Name: MFRW
Variable Units: LBM/SEC
Variable Calc Upper Limit: 100000000
Variable Calc Lower Limit: 0
Variable Type: Output
Variable Format: REAL
Variable Notes:

Variable Description: Comments
Variable Label Description: Comments
Variable Calc Name: COM
Variable Units:
Variable Calc Upper Limit:
Variable Calc Lower Limit:
Variable Type: Output
Variable Format: TEXT
Variable Notes: Displays "Input(s) out of range." if an entered input variable(s) are out of range. Displays "Output(s) out of range." if an output variable exceeds its range. The "out of range" variable(s) are displayed in yellow. The limited range values are used in the calculation, not the "out of range" value(s).

Variable Description: Upstream (Large) Pipe (inside) Diameter at Entrance of Fitting
Variable Label Description: Pipe Upstream Inside Diameter
Variable Calc Name: PID
Variable Units: IN
Variable Calc Upper Limit: 300
Variable Calc Lower Limit: 0.01
Variable Type: Input
Variable Format: REAL
Variable Notes:

Variable Description: Beta of Valve Throat Diameter to Inside diameter of Inlet Pipe
Variable Label Description: Valve Beta
Variable Calc Name: BVAL
Variable Units:
Variable Calc Upper Limit: 1
Variable Calc Lower Limit: 0.05
Variable Type: Input
Variable Format: REAL
Variable Notes: See diagram on page A-27 of reference

Variable Description: Fitting Upstream Pressure
Variable Label Description: Upstream Pressure
Variable Calc Name: UPA
Variable Units: PSIA
Variable Calc Upper Limit: 10000
Variable Calc Lower Limit: 0.001
Variable Type: Input
Variable Format: REAL
Variable Notes: This value is used to calculate the flow rate of the fluids through the valve.

Variable Description: Pressure Ratio = (UPA-DPRE)/(UPA) , Difference of Upstream Pressure & Downstream Pressure divided by the Upstream Pressure
Variable Label Description: Pressure Ratio
Variable Calc Name: DPA
Variable Units:
Variable Calc Upper Limit: 0.8
Variable Calc Lower Limit: 0.001
Variable Type: Input
Variable Format: REAL
Variable Notes: Cannot be greater than 0.8

Variable Description: Specified Fluid Density at Upstream Condition
Variable Label Description: Fluid Density
Variable Calc Name: DEN
Variable Units: LBM/CUFT
Variable Calc Upper Limit: 10000
Variable Calc Lower Limit: 0.001
Variable Type: Input
Variable Format: REAL
Variable Notes:


Eng-Calcs Home Page

Email: eng-calc@eng-calcs.com


Copyright @ 2006 Eng-Calcs.Com